Place of Origin | China |
Brand Name | JT-RESIN |
Certification | SGS,CE,UL |
Model Number | JT8218A/B |
Epoxy electrical insulation OF ROOM TEMPERATURE CURING FOR COIL FRAME WORK
PRODUCT MSDS:
1. IDENTIFICATION
Commodity name: JT 8054A Modified epoxy resin
Company Name: HUBEI JIANGTE INSULATION COMPOSITE CO., LTD.
Add: Room219 Zhanghua Road(N), EDA Qianjiang City, Hubei Province, China
Tel:+86-728-6201068
Fax:+86-728-6202066
Zip code:433132
2. HAZARDS IDENTIFICATION
Irritating to eyes and skin.
May cause sensitization by skin contact.
Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
3. COMPOSITON INFORMATION ON INGREDIENT
Chemical Name | CAS No. | Content(%) |
4,4'-(1-methylethylidene)bisphenol polymer with (chloromethyl)oxirane | 25068-38-6 | >90.0 - <100.0 |
Poly(propylene glycol) | 25322-69-4 | >0.0 - <10.0 |
Product TDS:
Epoxy Electrical Insulation System
JT 8218A Epoxy Resin 100 pbw JT 8218B Epoxy Hardener 20-25 pbw |
|
Used for:low voltage CT(and zero-sequence instrument transformers) | |
electronic components such as: ignition, regulator, electronic transformers, network transformers, pump motor, ignition coil, transformer, negative ion generator, AC capacitor, (vertical, horizontal, cartridge, film capacitor), power module, LED module, insulating pouring lamps etc. Appropriate operation time, easy to produce the work. Can withstand high and low temperature curve, with excellent electrical properties and physical properties.
|
Applications |
For common vacuum casting processing, the typical mould temperature is 70℃–80℃, demoulding time( different as per temperature and volume) is about 5-8h. Keeping 10h at 130℃ after curing. Demoulding time and after-curing cycle need to be determined as per specific product design and technology. Please kindly contact our techanicians for more information
|
Processing methods |
Room Temperature curing Good flame reardant Low viscosity Good impregnation Long pot life Good adhesion to the coil skeleton |
Properties |
|
Product data(Guideline values) *
JT 8218 A modified Epoxy resin
TYPICAL VALUES* |
Viscosity @ 25℃, mPa.s [ISO 2555] .....................................................................2,000-6,000 Density @ 25℃ , g/cm3 [ISO 1675] ........................................................................ 1.50-1.70 Storage life @ 25℃ (sealed container), month …………………………………………….………………..12 |
Remark:In order to prevent the absorption of moisture,please keep epoxy resin in sealed container and storage under normal temperature (about 20 to 25℃).
JT 8218 B Modified liquid hardener
TYPICAL VALUES* |
Viscosity @ 25℃, mPa.s [ISO 2555] .............................................................................30-300 Vapour Pressure @ 25℃, mbar .........................................................................................1-2 Density @ 25℃ , g/cm3 [ISO 1675] .........................................................................0.95-1.05 Storage life @ 25℃ (sealed container), month ……………………………………………………………...12 |
Process parameters(guideline values)*
System:JT 8218A / JT 8218B
TYPICAL VALUES* |
JT 8218A Epoxy resin ……………………………………….....................................................100 pbw JT 8218B Epoxy hardener……………………………………….................................................25 pbw |
TYPICAL VALUES* |
Initial Mixed Viscosity @ 40℃, mPa.s [ISO 2555] ..................................................1500-3000
Gel time, 25℃, Gelnorm instrument, minute ................................................................30-60
|
*Guideline values, for reference only!
Properties(guideline values)*
Curing condition: 24 h@25℃+6h@60℃
TYPICAL VALUES* |
Hardness@25°C, Shore D................................................................................................70-80
Tensile strength@, MPa.................................................................................................... >10
Flexural strength@, MPa................................................................................................... >40
Coefficient of linear thermal expansion@, ppm/K...................................................... 50-100
Thermal conductivity@, Wm/k …………………………………………………………………………………… >0.4
Dielectric strength@, kV/mm............................................................................................ >15
Dielectric constant@25°C ,50HZ...................................................................................4.0-5.0
Volume resistivity@ Wcm………………………………………………………………………………….………1X1015
|
Industrial hygiene
When operating and processing products, must follow the industrial hygiene standards.
For more information, please refer to the corresponding safety data sheet and
Operating protection measures
Workplace safety measures:
Protective clothing Need
Gloves Must need
Arms to protection May contact with the skin, Recommended
Goggles/safety glasses Need
Mask/dust mask Recommended
Skin protection:
Before working To exposed skin protection by cream
After washing Frost of besmear protective cream or nutrition
Contamination of the skin clean With suction paper wipe, wash with warm water and alkali free soap, With a one-time towel dry. Do not use solvents.
Clean workshop environment Use a light paper covering the table and chairs. Using a disposable beaker, etc. Spatter material processing Use sawdust or waste cotton silk blotting, and placed in a plastic woven baskets.
Ventilation:
To workshop Take a breath three to five times per hour.
To position Cover of exhaust fan. The operator should avoid inhalation of vapour.
Application area: