Product Details
Shape:
Liquid
Color:
White
Industry:
Electrical Insulator
Thermal Class:
H
Application Environment:
High Temperature
Name:
Epoxy Electrical Insulation System
Process:
Conventional Vacuum Self Gravity Casting
Proportioning:
100:100
Classification:
Double Components Adhesives
Usage:
Electrical Insulation
Cas No.:
50-28-2
Main Raw Material:
Epoxy
Highlight: 

Pre - Filled Transformer Epoxy Resin

,

Fast Cure Transformer Epoxy Resin

,

Liquid Fast Cure Epoxy Resin

Payment & Shipping Terms
Minimum Order Quantity
25KG
Price
$3/kg
Packaging Details
1200kgs/pail
Delivery Time
5 days
Payment Terms
L/C, T/T, Western Union, MoneyGram
Supply Ability
200Ton/week
Product Description

HUBEI CHINA FACTORY PRODUCE PRE-FILLED CASTING EPOXY RESIN FOR DRY TYPE TRANSFORMERS CLASS H

MSDS:

 

1. IDENTIFICATION

Commodity name: JT 8055A Modified epoxy resin

Company Name: HUBEI JIANGTE INSULATION COMPOSITE CO., LTD.

Add: Room219 Zhanghua Road(N), EDA Qianjiang City, Hubei Province, China

Tel:+86-728-6201068

Fax:+86-728-6202066

Zip code:433132

Pre - Filled Transformer Epoxy Resin Casting Fast Cure Liquid For Dry Transformer 0

 

 

2. HAZARDS IDENTIFICATION

Irritating to eyes and skin.

May cause sensitization by skin contact.

Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

 

 

3. COMPOSITON INFORMATION ON INGREDIENT

Chemical Name CAS No. Content(%)
4,4'-(1-methylethylidene)bisphenol polymer with (chloromethyl)oxirane 25068-38-6 >40.0 - <50.0%
Silica flour 14808-60-7 >45.0 - <55.0%

Pre - Filled Transformer Epoxy Resin Casting Fast Cure Liquid For Dry Transformer 1Pre - Filled Transformer Epoxy Resin Casting Fast Cure Liquid For Dry Transformer 2Pre - Filled Transformer Epoxy Resin Casting Fast Cure Liquid For Dry Transformer 3

 

4. FIRST AID MEASURES

A. Eye contact

- Do not rub your eyes.

- Immediately flush eyes with plenty of water for at least 15minutes and call a doctor/physician.

 

B. Skin contact

- Flush skin with plenty of water for at least 15minutes while removing contaminated clothing and shoes.

- Laundering enough contaminated clothing before reuse.

- Go to hospital immediately if symptoms(flare, irritate) occur.

- Wash thoroughly after handling.

 

C. Inhalation contact

- When exposed to large amounts of steam and mist, move to fresh air.

- Take specific treatment if needed.

 

D. Ingestion contact

- About whether I should induce vomiting. Take the advice of a doctor.

- Rinse your mouth with water immediately.

 

E. Delayed and immediate effects and also chronic effects from short and long term exposure

- Not available

 

F. Notes to physician

- Notify medical personnel of contaminated situations and have them take appropriate protective measures.

 

 

5. FIRE-FIGHTING MEASURES

A. Suitable (Unsuitable) extinguishing media

- Dry chemical, carbon dioxide, regular foam extinguishing agent, spray

- Avoid use of water jet for extinguishing

 

B. Specific hazards arising from the chemical

- Not available

 

C. Special protective actions for firefighters

- Notify your local firestation and inform the location of the fire and characteristics hazard.

- Using a unattended and water devices in case of large fire and leave alone to burn if you do not imperative.

- Avoid inhalation of materials or combustion by-products.

- Do not access if the tank on fire.

- Use appropriate extinguishing measure suitable for surrounding fire.

- Keep containers cool with water spray.

- Vapor or gas is burned at distant ignition sources can be spread quickly.

 

 

6. ACCIDENTAL RELEASE MEASURES

A. Personal precautions, protective equipment and emergency procedures

- Must work against the wind, let the upwind people to evacuate.

- Move container to safe area from the leak area.

- Remove all sources of ignition.

- Do not direct water at spill or source of leak.

- Avoid skin contact and inhalation.

 

B. Environmental precautions

- Prevent runoff and contact with waterways, drains or sewers.

- If large amounts have been spilled, inform the relevant authorities.

 

C. Methods and materials for containment and cleaning up

- Large spill : Stay upwind and keep out of low areas. Dike for later disposal.

- Notification to central government, local government. When emissions at least of the standard amount

- Dispose of waste in accordance with local regulation.

- Appropriate container for disposal of spilled material collected.

- Small leak: sand or other non-combustible material, please let use absorption.

- Wipe off the solvent.

- Dike for later disposal.

- Prevent the influx to waterways, sewers, basements or confined spaces.

 

 

7. HANDLING AND STORAGE

A. Precautions for safe handling

- Wash thoroughly after handling.

- Avoid direct physical contact.

- Avoid contact with incompatible materials.

- Refer to Engineering controls and personal protective equipment.

- Do not inhale the steam prolonged or repeated.

 

B. Conditions for safe storage, including any incompatibilities

- Do not use damaged containers.

- Do not apply direct heat.

- Save applicable laws and regulations.

- Avoid direct sunlight.

- Keep in the original container.

- Collected them in sealed containers.

- Do not eat, drink or smoke when using this product.

- Store away from water and sewer.

 

 

8. OPERATION DISPOSAL AND STORAGE

Note: closed/sealed operation, provide good natural ventilation condition. The operator must go through specialized training, strictly follow the operating rules. We suggest that the operating personnel wearing Self suction filtering type dust mask, and wearing protective chemical safety glasses.

Storage note: dry and ventilated

 

 

9. PHYSICAL AND CHEMICAL PROPERTIES

-Appearance  
a. Appearance Viscous paste
b. Color Red color
Odor Not available
-Odor threshold Not available
-PH Not available
-Melting point/Freezing point unapplied (liquid in room temperature)
-Initial Boiling Point/Boiling Ranges > 180 ℃(Estimated valued)
-Flash point Not available
-Evaporation rate Not available
-Flammability(solid, gas) Not available
-Upper/Lower Flammability or explosive limits Not available
-Vapour pressure Not available
-Solubility Not available
-Vapour density Not available
-Specific gravity(Relative density) 1.50-1.70g/cm3(at 25℃)
-Autoignition temperature Not available
-Decomposition temperature Not available
-Viscosity 1000-4000Pa.s(at 40℃)

 

 

10. STABILITY AND REACTIVITY

  1. Chemical Stability and Reactivity

- This material is stable under recommended storage and handling conditions.

 

B. Possibility of hazardous reactions

- Hazardous Polymerization will not occur.

 

C. Conditions to avoid

- Avoid contact with incompatible materials and condition.

- Avoid Accumulation of electrostatic charges, Heating, Flames and hot surfaces.

 

D. Incompatible materials

- Not available

 

E. Hazardous decomposition products

- May emit flammable vapour if involved in fire.

 

 

11. TOXICOLOGICAL INFORMATION

Acute oral toxicity : LD50 rat

Dose: > 2,000 mg/kg

Eye irritation : irritating rabbit

Method: Data based on tests on similar product.

Skin irritation: irritating rabbit

Method: Data based on tests on similar product.

dermal

Sensitization: Causes sensitization. Guinea pig

Method: Data based on tests on similar product.

Dermal

 

 

12. ECOLOGICALINFORMATION

Ecological toxicity: unknown

Biological degradation: unknown

Non biological degradation: unknown

 

 

13. DISPOSAL CONSIDERATIONS

A. Disposal methods

- Since more than two kinds of designed waste is mixed, it is difficult to treat separately, then can be reduction or stabilization by incineration or similar process.

- If water separation is possible, pre-process with Water separation process.

- Dispose by incineration.

- Incinerate the oil by separating the oil and water

- The remainder of the water after separation will be processed in a water pollution prevention facilities.

- Do incineration or stabilization of the residue after disposal as the method of evaporation and concentration.

- Do incineration of the residue after disposal as the method of agglomeration and precipitation.

- Take care of incinerate or stabilization after treatment, purified by means of Separation distillation extraction filtration pyrolysis

 

B. Special precautions for disposal

- The user of this product must disposal by oneself or entrust to waste disposer or person who other’s waste recycle and dispose, person who establish and operate waste disposal facilities.

- Dispose of waste in accordance with all applicable laws and regulations.

 

 

14. TRANSPORT INFORMATION

A. UN No. (IMDG)

- Non Hazmat

 

B. Proper shipping name

- Non Hazmat

 

C. Hazard Class

- Non Hazmat

 

D. IMDG Packing group

- Non Hazmat

 

E. Marine pollutant

- Non Hazmat

 

F. Special precautions for user related to transport or transportation measures

- Local transport follows in accordance with Dangerous goods Safety Management Law.

- Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

- EMS FIRE SCHEDULE : Non Hazmat

- EMS SPILLAGE SCHEDULE : Non Hazmat

 

 

15. REGULATORY INFORMATION

National legislation

Water contaminating class : 2 water endangering

Classified according to annex 4 of the German VwVwS for preparations.

 

Notification status : EINECS yes

: TSCA yes

: DSL yes

: INV (CN) yes

: PICCS (PH) yes

: KECI (KR) yes

: JEX (JP) yes

 

16. OTHER INFORMATION

  1. Reference

- The information contained herein is believed to be accurate. It is provided independently of any sale of the product for purpose of hazard communication. It is not intended to constitute performance information concerning the product. No express warranty, or implied warranty of merchantability or fitness for a particular purpose is made with respect to the product or the information contained herein.

 

  1. Last date revised

- 2019.12.31

 

  1. Other

- This SDS is prepared according to the Globally Harmonized System (GHS).

Pre - Filled Transformer Epoxy Resin Casting Fast Cure Liquid For Dry Transformer 4Pre - Filled Transformer Epoxy Resin Casting Fast Cure Liquid For Dry Transformer 5

 

 

Contact Us at Any Time

86-20-82320316
Room 606, Donghong International Plaza, No. 113 Chebei Road, Tianhe District, Guangzhou, China
Send your inquiry directly to us